Open type 50Hz 275kw 344kva Cummins NTA855-G2A engine diesel generator set
Original design 50Hz 275kw 344kva Cummins NTA855-G2A engine diesel generator set, powered with Cummins NTA855-G2A diesel engine, coupled with standard China alternator, optional auto transfer switch, suitable for developing countries. Please feel free to contact Gosun once you have the generator set order.
Technical Specifications
GENERATOR SET OUTPUT INFORMATION
Model No. | Voltage | Hz | Phase & Wires | Power Factor (cosφ) | Standby Current ( A) | Standby Power ( KW / KVA ) | Rated Power ( KW / KVA) |
275GF-C50 | 440/254 | 50 | 3 phases 4 wires | 0.8 lagging | 492 | 300/375 | 275/344 |
275GF-C50 | 415/240 | 50 | 3 phases 4 wires | 0.8 lagging | 521 | 300/375 | 275/344 |
275GF-C50 | 400/230 | 50 | 3 phases 4 wires | 0.8 lagging | 541 | 300/375 | 275/344 |
275GF-C50 | 380/220 | 50 | 3 phases 4 wires | 0.8 lagging | 569 | 300/375 | 275/344 |
ENGINE SPECIFICATIONS
ENGINE PARAMETERS
Manufacturer / Model | Cummins NTA855-G2, 4-cycle |
Air Intake System | Turbo, air / water cooling |
Fuel System | PT-type fuel pump, EFC |
Cylinder Arrangement | 6 inline |
Engine Displacement | 14 L |
Bore*Stroke | 140*152 (mm) |
Compression Ration | 14.0:1 |
Rated Speed (RPM) | 1500rpm |
Engine Max Power | 343 KW |
Governor Type | Electronic |
FUEL CONSUMPTION
100% Load | 191.3 g/kw.h |
75% Load | 194.9 g/kw.h |
50% Load | 207.1 g/kw.h |
LUBE SYSTEM
Lube Consumption | ≤ 4 g/kw.h |
Oil Pressure At Rated Speed | 241-345 kPa |
ALTERNATOR SPECIFICATIONS
Number Of Phases | 3 |
Connection Type | 3 phase 4 wires, Y-type connection |
Bearing Numbers | 1 |
Power Factor (cosφ) | 0.8 (lagging) |
Protection Grade | IP23 |
Altitude | ≤ 1000 meters |
Excitation Mode | Brushless, self-exciting |
Insulation Grade | H |
Rated Capacity | 350 KVA |
Alternator Efficiency | 93.5% |
CONTROL PANEL FEATURES ( DSE7320 MKII AUTO MAINS FAILURE / UTILITY CONTROL MODULE )
Support for O-10 V & 4-20mA oil pressure senders.
Large back-lit icon LCD display.
Heated display option.
3-phase generator sensing.
3-phase generator and mains (utility) sensing
Breaker control buttons on the front fascia.
Generator & load power monitoring (kW, kV A, kV Ar, pf).
Generator overload protection (kW).
Generator/load current monitoring & protection
Configurable analogue/digital inputs.
Configurable DC, volt-free and staged loading outputs.
CAN, MPU & alternator speed sensing ( selectable depending on engine type).
Tier 4 CAN engine support.
DIMENSION & WEIGHT
Open-type size ( with base fuel tank) | 3030*1100*1850 (mm) |
Gross Weight | 2870 kg |
MANUFACTURING STANDARDS
All our diesel generators are designed and manufactured in accordance with international standards, such as EN60O34, BS50O0, IEC34-1, GB755, VDE0530, CSA22.2, AS1359, as well as the requirements of ISO9001 and ISO14O01.
SUPPLY SCOPE
1. Cummins NTA855-G2A engine
2. Alternator
3. DSE7320 MKII control panel
4. standard radiator mounted on skid
5. high-grade steel base frame (optional base fuel tank )
6. electronic governor
7. battery charger
8. cranking motor
9. English operation manual, maintenance and test reports.
10. accessories: rubber anti-vibrator, muffler, elbow, expansion joints, battery cables, battery
NOTICE
Pictures associated with this page are for illustration only, they may not reflect the actual product, please contact us to get the actual product image. The above technical specifications are for reference only, we reserved the right to change the configuration without notifying website visitors, please contact our sales or technical team for final confirmation.